Research Highlights · Faculty Perspective · Micro/nano-electronics · Biosensors · MEMS

CHIPS Lab

Electronic devices that bring diagnosis and sensing out of the laboratory and to the point of need: for infection, food safety, water and eye health.

Led byProf. Shiv Govind SinghProfessor, Department of Electrical Engineering, Indian Institute of Technology Hyderabad
Point-of-care diagnosticsLab-on-chip3D-ICRF MEMSNano-biosensorsRetinal AI screening
On this page
Back to Research Highlights

Research areas

Micro/nanotechnology

Design, fabrication and characterisation of devices at the micro and nano scale.

3D integrated circuits

3D-IC technology, interconnects and electromigration, with electrical and thermal modelling.

RF MEMS

Design, simulation, fabrication and testing of RF MEMS, including micro-bolometers and ultrasonic transducers.

Nano-biosensors and point-of-care diagnostics

Sensors that read disease biomarkers electrically, on low-cost platforms.

Lab-on-chip, micro/nanofluidics

Compact chips that move and sense very small sample volumes.

Electronics cooling and energy

Electronics cooling, 3D solar cells and ultra-low-power solar energy-harvesting circuits.

Flagship work

COVIHOME: AI-powered electronic point-of-care test kit

AI-powered, low-cost, point-of-care electronic testing kit (X-HOME) for tele-diagnostics and tele-medicine

How a test works

  1. 1Collect.An oral or nasopharyngeal swab sample is taken.
  2. 2Capture.The sample goes onto a disposable biochip whose capture bio-molecules bind the viral RNA.
  3. 3Measure.The readout circuit records the electrical current before and after RNA is immobilised on the sensor.
  4. 4Decide.The Android app takes the chip ID, runs the algorithm on the change in current and shows a positive or negative result.

Why an electronic rapid test

The pandemic showed the need for indigenous, affordable, easy-to-use portable test kits. Laboratory testing and analysis took around 24–48 hours, and antigen colorimetric kits were faster but less efficient. The same gap exists in food quality, air, soil and water-toxicity testing, where samples travel to a distant laboratory and need trained technicians.

The kit has a sensing component, a processing component (a microcontroller running a predetermined algorithm or machine-learning model) and a display component. Sensor response is measured as electrical parameters, and sensor variability is handled by using the absolute change in those parameters. An Android app makes the result easy for a non-technical user to read. The same kit and sensor can be modified to detect pathogens in blood, bacteria in food and toxic content in water.

  • COVIHOME is India's first electronic rapid COVID-19 RNA test kit.
  • CCMB Hyderabad, an ICMR partner institute, validated it.
  • It is a smartphone-based point-of-care device that works on oral or nasopharyngeal swabs, with no RNA extraction and no RT-PCR.
  • A biochip captures the target, a miniaturised readout circuit measures it, and an Android app shows the result over an OTG connector.
  • Results come in about 20 to 30 minutes.
98.2%Specificity
91.4%Sensitivity
94.2%Efficiency
20 minTo result

How COVIHOME compares

TestDurationAverage cost
RT-PCR (gold standard)~8 hours₹1000
Antigen (low efficiency)~30 minutes₹400
COVIHOME20 minutes₹400 per biochip
Android-based low-cost portable read-out
Loading a sample onto the biochip

Extended applicability

  • Cardiac: Trop-I and T, CKMB, Hfab
  • Sepsis panel: CRP, PCT, IL-8, sTREM-1
  • Traumatic brain injury: UCHL-1 and GFAP
  • Fever panel: dengue, malaria, chikungunya
  • Dementia panel: AB 1-40, AB 1-42, Tau 181, T-Tau

A platform for a new virus or infection can be developed within one month.

Modified probe on the sensor detects different target species
1 customisable biochipAbout $5 per testUsable by 10th gradersTele-medicine readyHospitals, clinics, remote areas

COVIHOME was developed by a research team led by Prof. Singh, with Dr. Suryasnata Tripathy, Ms. Supraja Patta, Ms. Swati Mohanty and other students. Initial clinical testing was at ESIC Medical College and Hospital, Hyderabad, and a patent has been filed.

Portable lab-on-a-chip device for detecting adulteration in milk

Also known as Raj-Hans, named after the mythical bird said to separate milk from water

  • The device measures milk's inherent biophysical properties, pH and impedance, to spot adulteration and masking.
  • Pure milk falls in a narrow zone of purity: impedance of about 640 to 620 Ω and pH of 6.6 to 6.9.
  • Samples outside this zone are classed as adulterated. A pH sensor and an impedance sensor sit on the same chip.
  • Electrodes were built on glass and on PCB.
6.6–6.9pH of pure milk
640–620 ΩImpedance of pure milk
99.71%2018 classification accuracy
2Electrode types: glass, PCB

Timeline

  • 2017: a proof-of-concept portable device, developed with Prof. Siva Rama Krishna Vanjari, using milk's biophysical markers.
  • Nov 2018: a smartphone system that reads the colour of pH indicator paper with machine learning, published in Food Analytical Methods with Prof. Soumya Jana and Prof. Vanjari.
Classification on impedance and pH, with the narrow zone of purity
Commercial adulterants affect pH, or both pH and impedance, or impedance
Adulteration and masking combinations tested for impedance and pH
Glass-based pH and impedance electrodes
PCB-based pH and impedance electrodes

NetraX Multi-condition retinal screening

Eight conditions. One retinal photo. Sixty seconds.

Smartphone attachment and offline AI, with no lab, blood draw or specialist

Major systemic and ocular diseases often stay hidden until late stages. Care today relies on separate blood draws and specialist visits, with panels costing over ₹6,400. NetraX screens for all eight conditions from a single retinal photograph, in 60 seconds per eye.

Chronic kidney diseaseCoronary artery diseaseLiver diseaseCarotid intima-media thicknessDiabetic retinopathyGlaucomaAMDHypertensive retinopathy
  • Runs offline on existing hospital fundus cameras, at a ₹1.2 lakh per year software licence.
  • Expanding to a portable smartphone attachment for primary care and rural screening.
  • "Glass-box" design: it quantifies named retinal vessel features first, then predicts risk.
  • Evaluated retrospectively on more than 700 patients and 1,000 fundus records (ESIC Hyderabad) plus public ophthalmic datasets.
8Conditions
60 sPer eye
>700Patients
0.14 mmCIMT error*
NetraX analysis screen: one retinal photo, eight risk readouts (illustrative)

Reported AUROC by condition

Age-related macular degeneration0.995
Chronic kidney disease0.989
Diabetic retinopathy0.987
Coronary artery disease0.983
Glaucoma0.965
Hypertensive retinopathy0.949
Liver disease*0.946

Bars run from 0.5 to 1.0. *Validated, pending software integration. Retrospective results. Screening support only; not a diagnostic device.

Looking for clinical partners

Clinical partners are sought for prospective multi-site validation and for new organ-pathway cohorts: lung, brain, fundus-to-OCT, hs-CRP, lipids and expert vessel annotation. Study protocols, IEC paperwork and software tools are provided, with joint publications. To collaborate, write to sgsingh@iith.ac.in.

More projects Sensors, 3D-IC and MEMS

Gas sensing

Ammonia sensor on 2D ZnO nanoflakes

A reversible chemiresistive sensor for ammonia, a harmful gas from chemical plants, automobiles and agricultural waste.

80%Maximum response
<15 sResponse and recovery
0.6–3 ppmNH3 range
  • Operates at 250 °C on 2D ZnO nanoflakes.
  • Response and recovery times are under 15 seconds across 0.6 to 3 ppm of NH3.
  • Drift correction is part of the design, for environmental monitoring.
Gas sensing

Chemiresistive sensors for vehicular emissions

Selective, sensitive sensors to replace slow, expensive instruments for air-pollutant and greenhouse-gas monitoring.

  • Four sensors detect CO and NO2 (CdS-based, with different electrode metals) and CO2 and CH4 (single-phase high-entropy oxides).
  • The choice of electrode sets the contact barrier and so which gas the sensor answers to.
  • Humidity-independent methane detection and transient analysis to shorten measurement time were also explored.
Water quality

Atrazine detection in water

Label-free electrochemical sensing of the pesticide atrazine, which harms people, animals and plants.

0.9 zMLimit of detection
1 zM–1 µMDynamic range
Label-freeTransduction
  • Electrospun SnO2 nanofibres detect atrazine from 1 zM to 1 µM.
  • The limit of detection is 0.9 zM.
  • Spiked real water samples were tested, a step towards field use.
Cardiac diagnostics

Troponin biosensors for early heart-attack detection

Impedance-based electrodes that detect cardiac troponin at far lower concentrations than current methods.

10,000×Below current limit
1 fg/mLLowest range tested
Label-freeSensing
  • An antibody-coated bioelectrode detects troponin T at a concentration 10,000 times lower than the current limit of detection.
  • As more biomarker binds the antibody, impedance rises; that rise is the measured signal.
  • A ZnSnO3 perovskite electrode reaches sub-femtomolar troponin T detection from 1 fg/mL to 1 µg/mL.
3D integrated circuits

Low-temperature Cu–Cu bonding for 3D-IC

Low-temperature, low-pressure Cu–Cu bonding is a bottleneck for stacking chips in 3D.

<100 °CCu–Cu bonding
140 °CAt 4 bar
150 °CWafer on wafer
  • Cu–Cu thermocompression bonding at 140 °C and a nominal contact force of 4 bar.
  • Engineering the surface stress features brought bonding below 100 °C, reported as a first.
  • Ultrathin copper-alloy passivation enabled 150 °C wafer-on-wafer bonding that resists oxidation and is CMOS compatible.
  • Applications include 3D resonators, 3D CMUTs and an on-silicon aperture-coupled patch antenna.
Flexible sensing

Silk piezoelectric tactile sensor

A silk-based, ultra-flexible tactile sensor that mimics human touch perception.

  • Reported as the first ultra-flexible tactile sensor built on piezoelectric silk thin film.
  • Fabrication needs only one lithography step and one spin-coating step, so it works in resource-constrained labs.
  • The response differs clearly for finger taps of different strength, and the sensor tracks wrist movements precisely.
  • The same silk film is used for a piezoelectric micromachined ultrasonic transducer (PMUT).
Thermal imaging

Indigenous micro-bolometers

Micro-bolometers are the sensors inside thermal imaging cameras.

  • A stiction-free bulk micromachining process gives reliable, robust hanging structures.
  • Vanadium pentoxide nanofibres were developed as infrared sensing material for bolometers.
  • The process work won a best paper award at ICMEMSS 2014.
Milk safety

Smartphone-based milk adulteration check

An earlier route to the milk-purity device: colour of a pH indicator paper, read by a phone.

99.71%Classification accuracy
pHIndicator paper
PhoneCamera readout
  • An algorithm on the phone reads the colour change of the indicator paper and converts it to a pH range.
  • Machine-learning classification of milk spiked with combinations of contaminants reached 99.71% accuracy.
  • Chromatography and spectroscopy need costly set-ups; this approach is low-cost and portable.

MEMS, nano-biosensors and gas sensors

MEMS and NEMS devices

  • A stiction-free bulk micromachining process for indigenous micro-bolometers, the sensors behind thermal imaging cameras.
  • Reliable hanging structures made by etching differentially along chosen silicon crystal axes. This work won a best paper award at ICMEMSS 2014.
  • V2O5 and LSMO nanofibres to improve resolution, and a proposed new way to integrate MEMS with ASICs.
  • SU8-based CMUTs for airborne use, and a silk-based PMUT.
  • One of the few groups studying the piezoelectric properties of silk for sensing, with flexible tactile sensors built from self-poled PVDF nanofibres.

Biosensors and diagnostics

  • Ultrasensitive nano-biosensors for biomarkers: malaria and cardiac markers by antibodies, and breast cancer and dengue by DNA hybridisation.
  • A "multistep randomisation process" to reduce electronic variability, and MWCNT-doped ZnO electrospun nanowires.
  • The sensors keep for 8 weeks without packaging and can be reused with up to 10% sensitivity loss.
  • Avanteal Diagnostics (USA) is commercialising this technology.
  • Invitations to collaborate from KIMS Hospitals and LVPEI in Hyderabad, and Little Flower Hospital in Kochi.

Recent publications, 2023–2024

  • Electrochemical nano-biosensor for complement component 3 protein, using electrospun indium zinc oxide nanofibres (2023).
  • Tear-based MMP-9 detection for ocular inflammatory disorders, using vanadium disulfide nanowires (2023).
  • An ultra-flexible tactile sensor from silk piezoelectric thin film (2023).
  • A WO3-functionalised electrochemical aptasensor for ultra-trace arsenic in lake water, in Sensors and Actuators B (2024).
  • Tuberculosis volatile organic compound detection with MWCNT–ZnO nanofibre (2024 conference paper).

Recognition

  • Second-best poster, IEEE Sensors 2017, GlasgowFor dengue viral DNA detection
  • Best paper award, ICMEMSS 2014For micro-bolometer fabrication work

Invited talks

  • CII Food Safety, Quality & Regulatory Summit, New Delhi, Dec 2018: milk purity checking
  • Gorakhpur University, Jan 2019: Indian technology from ancient to modern times
  • One-day biosensors workshop, IIT Madras, Nov 2017
  • NatFOE, IIT Bombay, 2017: milk adulteration detection
  • ISSS, IISc Bangalore, Jul 2017: electrospun zinc oxide nanowires for point-of-care diagnostics

Videos COVIHOME demonstrations

Each card opens the video on YouTube in a new tab.

CHIPS Lab · Department of Electrical Engineering · Indian Institute of Technology Hyderabad